Keith Sowards, M.S.
Clinical Physicist, Assistant Professor
Clinical Physicist, Assistant Professor
Education/Training
Institution and Location | Degree | Date | Field of Study |
---|---|---|---|
University of Kentucky | M.S. | 1999 | Health Physics |
University of Kentucky | B.S. | 1995 | Physics |
Positions and Honors
Positions and Employment | Date |
---|---|
Clinical Physicist | August 2002 – Present |
Selected peer-reviewed publications (in chronological order)
- A.S. Meigooni, K. Sowards, M. Soldano: Dosimetric Characteristics of the InterSource 103Palladium Brachytherapy Source. Medical Physics 27(5), 1093-1100 (2000).
- C. Popescu, J. Wise, K. Sowards, A.S. Meigooni, and G. S. Ibbott: Dosimetric Characteristics of the PharmaSeed TM Model BT-125-1 Source. Medical Physics 27(9), 2174-2281 (2000).
- Ali S. Meigooni, K. Sowards, D. Gearheart: Experimental Determination of Dosimetric Characteristics of Best 125I Brachytherapy Source. Medical Physics 27(9), 2168-2173 (2000).
- D. Gearheart, A. Drogin, K. Sowards, A.S. Meigooni, and G.S. Ibbott: Dosimetric Characteristics of a New 125I Brachytherapy Source. Medical Physics 27(10), 2278-2285 (2000).
- A.S. Meigooni, S.A. Dini, K. Sowards, J.L. Hayes, and A. Al-Otoom: Experimental Determination of the TG-43 Dosimetric Characteristics of EchoSeed™ Model (6733 Brachytherapy Source. Medical Physics 29(6), 939-942 (2002).
- A. Meigooni, K. Sowards, G. Myron: Evaluation of the QZ Veridose Patient Monitoring Phantom. Medical Dosimetry Journal 29:49-54 (2003).
- A. Meigooni, G. Myron, K. Sowards: Evaluation of the Veridose Invivo Dosimetry System. Medical Dosimetry 27:29-36 (2002).
- A.S. Meigooni, M.M. Yoe-Sein, A.Y., Al-Otoom, and K.T. Sowards: Determination of the Dosimetric Characteristics of InterSource 125Iodine Brachytherapy Source. Applied Rad & Isotopes 56:589-599 (2002).
- Ali S. Meigooni, Joshua Hayes, Hualin Zhang, and Keith Sowards: Experimental Determination of IsoAid ADVANTAGE™ 125I Brachytherapy Source. Medical Physics 29(9):2152-2158 (2002).
- A.S. Meigooni, Z. Bharucha, M. Yoe-Sein, and K.T. Sowards: Dosimetric characteristics of the Best® double-wall 103Pd brachytherapy source. Med Phys 28(12):2568-2575 (2001).
- K.T. Sowards, A.S. Meigooni: A Monte Carlo evaluation of the dosimetric characteristics of the Best ® Model 2301 125I Brachytherapy Source. Applied Radiation and Isotopes 57:327-333 (2002).
- K.T. Sowards, A.S. Meigooni: A Monte Carlo evaluation of the dosimetric characteristics of the Amersham model 6733 125I brachytherapy source. Brachytherapy Vol. 1(4):227-232 (2002).
- Erratum: “Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ 125I brachytherapy source” [Med. Phys. 29, 2152–2158 (2002)], Med. Phys. 30, 279 (2003).
- K.T. Sowards: Monte Carlo Dosimetric Characterization of the IsoAid ADVANTAGETM 103Pd Brachytherapy Source. Journal of the American College of Medical Physics, Vol 8, No 2, (2007).
- K.T. Sowards, C.M. Luerman, A.S. Meigooni: Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources. Med Phys 36(4):1452-1458 (2009).