Other Instruments

Atomic Absorption Spectroscopy (AAS)

Atomic Absorption Spectroscopy(iCETM 3000, Thermo Scientific)

The Thermo Scientific™ iCE™ 3000 AAS offers a simple and reliable solution for trace elemental analysis. With options to configure the instrument as a dedicated flame, dedicated furnace or flame and furnace system, this is a truly versatile analyzer. Robust enough for samples with high levels of dissolved solids or acids.

  • Increase your sample through-put and limit downtime with productivity enhancing technology
  • Optimization routines can be included in the method to ensure truly optimal parameters
  • Thermo Scientific™ SOLAAR™ software offers ultimate ease-of-use with extensive help functions, automated performance controls and wizards
  • Self-calibrating monochromators and auto-aligning lamps offer simple optical setup and optimum light throughput in dedicated Flame system
  • Parts-per-billion ultra-trace detection capability from dedicated Graphite Furnace system

HPLC

HPLC(Agilent 1200 LC System. Agilent)

The Agilent 1200 nanoflow LC System enables users to achive new levels of productivity, processing more samples in less time, while maintaining and even improving data quality. Short columns with sub-2 μm particles offer a unique opportunity to dramatically reduce analysis time by increasing the flow rate without losing separation performance.

  • Unsurpassed nanoflow performance and stability
  • Up to 3500 times more sensitive compared to conventional LC
  • Typical flow rates 0.1 – 1 μL/min, extendable up to 2.5 mL/min

HPLC

HPLC(UltiMate 3000 Standard LC System. Thermo Scientific)

UltiMate® 3000 Standard LC system is perfectly matched to meet requirements of low extracolumn and gradient delay volume for high separation efficiency and low gradient response times, as well as superior mixing performance. Analytical systems are UHPLC compatible with pressures up to 62 MPa (9000 psi).

  • Quaternary UHPLC system with extended pressure range up to 1250 bar, enabling the use of very long, sub-2 μm particle columns
  • Flow rate ranging from 20 nL/min to 10 mL/min
  • The unique 45 nL UV-monitor is especially designed for dispersion-free UV detection in LC/MS
  • The Thermostat­ted Column Compartment which easily holds up to six 250 mm columns, making column switching an easy step between projects
  • Lowest delay volume for ultrafast, ballistic gradients with up to four solvents
  • Capable of  two-dimensional LC separation